The CytoTox 96® Non-Radioactive Cytotoxicity Assay is a colorimetric alternative to radioactive cytotoxicity assays. The assay quantitatively measures lactate dehydrogenase (LDH), a stable cytosolic enzyme that is released upon cell lysis, in much the same way as [51Cr] is released in radioactive assays. Released LDH in culture supernatants is measured with a 30-minute coupled enzymatic assay that results in the conversion of a tetrazolium salt (INT) into a red formazan product. The amount of color formed is proportional to the number of lysed cells. Visible wavelength absorbance data are collected using a standard 96-well plate reader. The assay can be used to measure membrane integrity for cell-mediated cytotoxicity assays in which a target cell is lysed by an effector cell, or to measure lysis of target cells by bacteria, viruses, proteins, chemicals, etc.
The CytoTox 96® Non-Radioactive Cytotoxicity Assay requires no radioactive waste disposal or [51Cr] and eliminates labeling of target cells prior to conducting experiments. Standard equipment can be used to collect absorbance (visible wavelength) data with a standard 96-well plate reader. The assay can be used for a variety of applications including measurement of 1) cell-mediated cytotoxicity; 2) chemical-mediated cytotoxicity; and 3) total cell number. A highly sensitive assay, it can reveal early, low-level damage to cell membranes that is often missed with other methodologies.
Protocols
Specifications
Catalog Number:
What's in the box?
| Item | Código | Tamanho |
|---|---|---|
|
Substrate Mix |
G179A | 5 × 1 vial |
|
Assay Buffer |
G180A | 1 × 60ml |
|
LDH Positive Control |
G181A | 1 × 25μl |
|
Lysis Solution, 10X |
G182A | 1 × 5ml |
|
Stop Solution |
G183A | 1 × 65ml |
SDS
Search for SDSCertificado de Análise
Restrições de uso
For Research Use Only. Not for Use in Diagnostic Procedures.Condições de armazenamento
Store LDH Positive Control, Lysis Solution (10X) and Stop Solution at 4°C.
Resources
No related resources available
Related Products
Produtos semelhantes
LDH-Glo™ Cytotoxicity Assay
Bioluminescence-based LDH assay for sensitive detection of cytotoxicity in samples low in cell number, including 3D microtissues.
J2380, J2381, MG1010
CytoTox-Fluor™ Cytotoxicity Assay
A single-reagent-addition, homogeneous, fluorescent assay that measures the relative number of dead cells in cell populations.
G9260, G9261, G9262
CytoTox-ONE™ Homogeneous Membrane Integrity Assay
A homogeneous, LDH-based fluorometric method for quantifying non-viable cells.
G7890, G7891, G7892
CellTox™ Green Cytotoxicity Assay
Measures changes in membrane integrity. Kinetically monitors cytotoxicity up to 72 hours with multiplex capability.
G8741, G8742, G8743, G8731
Frequentemente usado com
Caspase-Glo® 3/7 Assay System
An easy-to-use, plate-based luminescent assay for detecting caspase-3/7 activity.
G8090, G8091, G8093, G8092, MG1010
Caspase-Glo® 8 Assay Systems
Measure caspase-8 activity with this homogeneous, luminescent assay.
G8200, G8201, G8202
CellTiter-Blue® Cell Viability Assay
Monitor cell viability with this homogeneous, resazurin, fluorescent assay.
G8080, G8081, G8082