Lumit® IL-1β Human/Mouse Immunoassay
No-Wash Immunoassay for IL-1β Detection in Cells
- Fast add-and-read protocol performed directly on cells
- Luminescent detection with just a standard plate-reading luminometer
- Scalable to 96- or 384- well plates, protocols included
- Pack sizes show assay number for 96-well plates
Catalog Number:
Choose a product
Size
Catalog Number: W6010
Catalog Number: W6011
Catalog Number: W6012
Catalog Number: W7010
Catalog Number: W7011
Catalog Number: W7012
Catalog Number: W116A-C
Catalog Number: W119A-C
Quantifique a Ativação do Inflamassoma sem Etapas de Lavagem Tediosas
O imunoensaio Lumit™ IL-1β mede quantitativamente a IL-1β liberada em amostras de cultura de células usando um protocolo simples e sem lavagem. Basta adicionar anticorpos marcados à amostra, adicionar o reagente de detecção e ler o sinal luminescente usando um luminômetro de leitura de placa padrão. Todo o protocolo é concluído em menos de 70 minutos! O ensaio pode ser usado diretamente nas células em cultura ou no meio de cultura transferido para uma placa de ensaio separada.
Como Funciona o Imunoensaio Lumit™ IL-1β
Protocolo Simples de Uma Placa, Sem Etapas de Lavagem!
Ampla Faixa Dinâmica de Detecção Lumit™
A faixa linear picomolar a nanomolar da detecção Lumit™ abrange as concentrações esperadas para a maioria dos modelos de células.
|
Assay |
IL-1β (Human) Immunoassay |
IL-1β (Mouse) Immunoassay |
|
Limit of Detection (LOD) |
10pg/ml (3 SD above background) |
8pg/ml (3 SD above background) |
|
Dynamic Range |
22pg/ml – 40ng/ml |
11pg/ml – 20ng/ml |
|
Minimal Detectable Dose (MDD) |
7pg/ml (2 SD above background) |
5pg/ml (2 SD above background) |
|
Assay Time |
70 minutes |
|
|
Sample Type |
Cell culture supernatants |
|
SD=Standard Deviation
Triagem de Inibidores de Inflamassoma NLRP3 de Alto Rendimento
The NLRP3 inflammasome inhibitor, MCC950, prevents caspase-1 activation and release of mature IL-1β. A titration of MCC950 was added to differentiated THP-1 cells (5 × 104/well) followed by LPS (20 EU/ml) or vehicle. The Lumit® IL-1β (Human) Immunoassay was performed after 5 hours.
Featured Publication
This peer-reviewed study "Interrogating direct NLRP3 engagement and functional inflammasome inhibition using cellular assays" examines the direct engagement and functionality of NLRP3 pathway activity in cells using several mechanistic assays, including the Lumit® IL-1β Immunoassay and Caspase-Glo 1 Inflammasome Assay.
Explore Outros Ensaios de Detecção de Citocinas
Oferecemos um crescente portfólio de ensaios para detecção de citocinas em amostras de cultura de células.
Não encontra seu alvo na lista?
Por favor, informe-se sobre o acesso antecipado a novos ensaios em desenvolvimento.
Para uma empresa de biotecnologia que entende que o tempo tem um valor significativo, os imunoensaios Lumit™ são uma forma essencial de coletar dados confiáveis rapidamente para que possamos chegar a conclusões e tomar decisões mais rapidamente.
Jonathan Chow, Cientista Principal, Corner Therapeutics
Specifications
Catalog Number:
What's in the box?
| Item | Código | Tamanho | Concentration |
|---|---|---|---|
Lumit® Detection Substrate B |
VB405A | 1 × 160μl | |
Lumit® Detection Buffer B |
VB406A | 1 × 3.2ml | |
Human IL-1β Standard |
W116A | 1 × 25μl | 10μg/ml |
Anti hIL-1β mAb-SmBiT, 1000X |
W117A | 1 × 15μl | |
Anti hIL-1β mAb-LgBiT, 1000X |
W118A | 1 × 15μl |
SDS
Search for SDSCertificado de Análise
Restrições de uso
For Research Use Only. Not for Use in Diagnostic Procedures.Condições de armazenamento
Please see the Protocol for detailed storage conditions.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
What's in the box?
| Item | Código | Tamanho | Concentration |
|---|---|---|---|
Lumit® Detection Substrate B |
VB405B | 1 × 1.25ml | |
Lumit® Detection Buffer B |
VB406B | 1 × 25ml | |
Human IL-1β Standard |
W116A | 1 × 25μl | 10μg/ml |
Anti hIL-1β mAb-SmBiT, 1000X |
W117B | 1 × 150μl | |
Anti hIL-1β mAb-LgBiT, 1000X |
W118B | 1 × 150μl |
SDS
Search for SDSCertificado de Análise
Restrições de uso
For Research Use Only. Not for Use in Diagnostic Procedures.Condições de armazenamento
Please see the Protocol for detailed storage conditions.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
What's in the box?
| Item | Código | Tamanho | Concentration |
|---|---|---|---|
Lumit® Detection Substrate B |
VB405A | 5 × 160μl | |
Lumit® Detection Buffer B |
VB406A | 5 × 3.2ml | |
Human IL-1β Standard |
W116A | 1 × 25μl | 10μg/ml |
Anti hIL-1β mAb-SmBiT, 1000X |
W117A | 5 × 15μl | |
Anti hIL-1β mAb-LgBiT, 1000X |
W118A | 5 × 15μl |
SDS
Search for SDSCertificado de Análise
Restrições de uso
For Research Use Only. Not for Use in Diagnostic Procedures.Condições de armazenamento
Please see the Protocol for detailed storage conditions.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
What's in the box?
| Item | Código | Tamanho | Concentration |
|---|---|---|---|
Lumit® Detection Substrate B |
VB405A | 1 × 160μl | |
Lumit® Detection Buffer B |
VB406A | 1 × 3.2ml | |
Mouse IL-1β Standard |
W119A | 1 × 25μl | 10μg/ml |
Anti mIL-1β mAb-SmBiT, 1000X |
W120A | 1 × 15μl | |
Anti mIL-1β mAb-LgBiT, 1000X |
W121A | 1 × 15μl |
SDS
Search for SDSCertificado de Análise
Restrições de uso
For Research Use Only. Not for Use in Diagnostic Procedures.Condições de armazenamento
Please see the Protocol for detailed storage conditions.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
What's in the box?
| Item | Código | Tamanho | Concentration |
|---|---|---|---|
Lumit® Detection Substrate B |
VB405B | 1 × 1.25ml | |
Lumit® Detection Buffer B |
VB406B | 1 × 25ml | |
Mouse IL-1β Standard |
W119A | 1 × 25μl | 10μg/ml |
Anti mIL-1β mAb-SmBiT, 1000X |
W120B | 1 × 150μl | |
Anti mIL-1β mAb-LgBiT, 1000X |
W121B | 1 × 150μl |
SDS
Search for SDSCertificado de Análise
Restrições de uso
For Research Use Only. Not for Use in Diagnostic Procedures.Condições de armazenamento
Please see the Protocol for detailed storage conditions.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
What's in the box?
| Item | Código | Tamanho | Concentration |
|---|---|---|---|
Lumit® Detection Substrate B |
VB405A | 5 × 160μl | |
Lumit® Detection Buffer B |
VB406A | 5 × 3.2ml | |
Mouse IL-1β Standard |
W119A | 1 × 25μl | 10μg/ml |
Anti mIL-1β mAb-SmBiT, 1000X |
W120A | 5 × 15μl | |
Anti mIL-1β mAb-LgBiT, 1000X |
W121A | 5 × 15μl |
SDS
Search for SDSCertificado de Análise
Restrições de uso
For Research Use Only. Not for Use in Diagnostic Procedures.Condições de armazenamento
Please see the Protocol for detailed storage conditions.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
What's in the box?
| Item | Código | Tamanho | Concentration |
|---|---|---|---|
Human IL-1β Standard |
W116A | 1 × 25μl | 10μg/ml |
SDS
Search for SDSCertificado de Análise
Restrições de uso
For Research Use Only. Not for Use in Diagnostic Procedures.Condições de armazenamento
Please see the Protocol for detailed storage conditions.
What's in the box?
| Item | Código | Tamanho | Concentration |
|---|---|---|---|
Mouse IL-1β Standard |
W119A | 1 × 25μl | 10μg/ml |
SDS
Search for SDSCertificado de Análise
Restrições de uso
For Research Use Only. Not for Use in Diagnostic Procedures.Condições de armazenamento
Please see the Protocol for detailed storage conditions.
Resources
Artigos
- Lumit® Cytokine Assays: Interpolating Data with the GloMax® Discover
- Blog Article: Understanding Inflammation: A Faster, Easier Way to Detect Cytokines in Cells
- Application Note: Culturing THP-1 Cells for Inflammasome Activation Assays
- High-Throughput Cytokine Detection with Lumit® Technology
- A Comprehensive Toolkit for NLRP3 Inflammasome Drug Discovery
- Targeted zinc-finger repressors to the oncogenic HBZ gene inhibit adult T-cell leukemia (ATL) proliferation
- Structural basis for thioredoxin-mediated suppression of NLRP1 inflammasome
- ACLY as a modulator of liver cell functions and its role in Metabolic Dysfunction-Associated Steatohepatitis
Related Products
Produtos semelhantes
Lumit® Active IL-18 (Human) Immunoassay
Quantitatively measure active IL-18 in cell culture samples using a simple, no-wash protocol completed in 70 minutes or less.
W1910, W1911, W1912, W191A-C
Lumit® IL-6 (Human) Immunoassay
Quantitatively measures released IL-6 in cell culture samples using a simple, no-wash protocol.
W6030, W6032, W6031, W128A-C
Lumit® IL-8 (Human) Immunoassay
Quantitatively measure IL-8 secretion in cell culture samples using a simple, no-wash protocol completed in 70 minutes or less.
W1460, W1461, W1462, W146A-C
Lumit® IL-17A (Human) Immunoassay
Quantitatively measure released IL-17A in cell culture samples using a simple, no-wash protocol completed in 70 minutes or less.
W1430, W1431, W1432, W143A-C
Lumit® IL-10 (Human) Immunoassay
Quantitatively measures released IL-10 in cell culture samples using a simple, no-wash protocol.
W6070, W6072, W6071, W131A-C
Lumit® TNF-α (Human) Immunoassay
Quantitatively measures released TNF-α in cell culture samples using a simple, no-wash protocol.
W6050, W6052, W6051, W137A-C
Lumit® HMGB1 Human/Mouse Immunoassay
HMGB1 quantitation with an add-mix-measure protocol completed in 90 minutes or less.
W6110, W6112, W140A-C
Frequentemente usado com
Caspase-Glo® 1 Inflammasome Assay
A homogeneous, bioluminescent method to selectively measure the activity of caspase-1, an essential component of the inflammasome.
G9951, G9952, G9953
Thaw-and-Use Primary Effector Cells
Consistent and robust method for target cell killing.
CS3055C02, CS3055C03, CS3055B03, CS3055B06, CS3055A15, CS3055A18
Lumit® Immunoassay Labeling Kit and Detection Reagents
Antibody labeling kit and detection reagents to help develop Lumit® Immunoassays.
VB2500, VB2010, VB2020, VB2030, VB4050, VB4060
GloMax® Discover System
High-performance microplate reader for detecting luminescence, fluorescence and absorbance.
GM3000