ONE-Glo™ + Tox Luciferase Reporter and Cell Viability Assay
Sensitive Detection of Reporter Activity and Cell Health
- Measures cell viability and firefly luciferase activity in the same assay well
- Easy to use—simply add reagent, mix and read
- Scalable to meet throughput needs, up to 1,536-well format
Catalog Number:
Size
Catalog Number: E7110
Catalog Number: E7120
Understand Reporter Gene Activity in the Context of Cell Viability
The ONE-Glo™ + Tox Assay combines luciferase assay chemistry with a cell viability marker to better understand reporter gene expression in the context of cell health. The assay uses a two-step, addition-only process to make these measurements in a single well of a plate, negating the need to run parallel assays. The simple "add-mix-read" assay format and optimized reagents combine to create a flexible, automation-friendly assay that can be scaled to meet your needs.
Step 1: Cell Viability Assay
In the first part of the assay, a nonlytic fluorescence-based method (CellTiter-Fluor™ Cell Viability Assay) is used to measure the relative number of live cells in culture. The CellTiter-Fluor™ Assay measures a conserved and constitutive protease activity within living cells. This live-cell protease activity is restricted to intact viable cells and is measured using a fluorogenic, cell-permeant peptide substrate (glycylphenylalanyl-aminofluorocoumarin; GF-AFC). The substrate enters intact cells where it is cleaved by the live-cell protease to generate a fluorescent signal proportional to the number of living cells. The live-cell protease becomes inactive upon loss of cell membrane integrity and leakage into the surrounding culture medium. Fluorescence of the free AFC fluorophore is measured with a microplate reader or CCD imager using an excitation wavelength of 380–400nm and emission wavelength of 505nm.
Step 2: ONE-Glo™ Luciferase Assay
The second part of the assay uses the ONE-Glo™ Luciferase Assay System to quantify firefly luciferase gene expression from cells expressing the reporter. Ideally suited for high- and ultrahigh-throughput applications, the ONE-Glo™ Assay Reagent contains a fluoroluciferin substrate that gives increased stability and greater tolerance of sample components, and has less odor than standard luciferase assay reagents. Luminescence is measured with a microplate reader or CCD imager.
Reference
Niles, A.L. et al. (2007) A homogeneous assay to measure live and dead cells in the same sample by detecting different protease markers. Anal. Biochem. 366, 197–206.
Schematic of the ONE-Glo™+Tox Luciferase Reporter and Cell Viability Assay.
Example ONE-Glo™ + Tox Assay Data
Ionomycin Titration in 96- and 384-well Plates
In the experiment shown here, 1 × 104 (96-well plate; Panel A) or 5 × 103 (384-well plate; Panel B) cells expressing NFAT response element were treated with serial titrations of ionomycin in the presence of PMA for 6 hours. At specific concentrations, ionomycin and PMA work cooperatively to stimulate NFAT-dependent gene expression. However, higher concentrations of ionomycin result in cytotoxicity seen as a decrease in viability (fluorescence). A decrease in reporter expression (luciferase) activity is also observed due to the increase in cytotoxicity.
Protocols
Specifications
Catalog Number:
What's in the box?
| Item | Código | Tamanho |
|---|---|---|
|
ONE-Glo™ Luciferase Assay Buffer |
E605A | 1 × 10ml |
|
ONE-Glo™ Luciferase Assay Substrate |
E606A | 1 × 1 vial |
|
GF-AFC Substrate |
G608A | 1 × 10μl |
|
Assay Buffer |
G610A | 1 × 10ml |
SDS
Search for SDSCertificado de Análise
Restrições de uso
For Research Use Only. Not for Use in Diagnostic Procedures.Condições de armazenamento
What's in the box?
| Item | Código | Tamanho |
|---|---|---|
|
ONE-Glo™ Luciferase Assay Buffer |
E605B | 1 × 100ml |
|
ONE-Glo™ Luciferase Assay Substrate |
E606B | 1 × 1 vial |
|
GF-AFC Substrate |
G608B | 2 × 50μl |
|
Assay Buffer |
G610B | 1 × 50ml |
SDS
Search for SDSCertificado de Análise
Restrições de uso
For Research Use Only. Not for Use in Diagnostic Procedures.Condições de armazenamento
Resources
No related resources available
Related Products
Produtos semelhantes
ONE-Glo™ EX Luciferase Assay System
Ensaio ONE-Glo™ aprimorado, adequado para a maioria das aplicações de firefly. Sinal mais duradouro do que o ONE-Glo™ Assay original, com maior estabilidade para uso e armazenamento flexíveis.
E8110, E8120, E8130, E8150
RealTime-Glo™ MT Cell Viability Assay
A bioluminescent method to kinetically monitor viability in cell culture up to 72 hours.
G9711, G9712, G9713
ApoTox-Glo™ Triplex Assay
Measure viability, cytotoxicity and apoptosis in one sample well to confirm mechanism of cell death.
G6320, G6321
Nano-Glo® Dual-Luciferase Reporter Assay System
Detecção ultrassensível das atividades da luciferase NanoLuc® e Firefly em uma única amostra.
N1610, N1620, N1630, N1650, N1521, N1531, N1541, N1551
Frequentemente usado com
Promoterless Firefly Luciferase Basic Vectors
Three pGL4 reporter vectors that express luciferase proteins with different stabilities for investigating gene expression control regions.
E6651, E6661, E6671
ViaFect™ Transfection Reagent
High-efficiency, low-toxicity transfection of many cell types, including iPS cells.
E4981, E4982
GloMax® Discover System
High-performance microplate reader for detecting luminescence, fluorescence and absorbance.
GM3000
FuGENE® HD Transfection Reagent
Desempenho otimizado numa ampla faixa de tipos de células, incluindo linhagens celulares de difícil transfecção